Welcome to the official website of Hangzhou Chinkoray GreenTek Co.,Ltd
Hotline:+86 1381359 3737
简体中文
3.5KW/7KW Pillar AC Charger
category:Product


Technical Parameters | |
|---|---|
Rated Power | 3.5 kW/7.0kW |
Charging Connector | Single gun |
| Display | 4.3-inch display screen (non-touch) |
Charging Method | RFID card swiping, optional QR code scanning |
| Charging Mode | Automatic full charge |
Installation Method | Wall-mounted / Floor-standing (pole) |
| Metering | Integrated on-board meter |
Surge Protection | Integrated on-board surge protection |
Output Characteristics | |
Output Voltage Range (V) | 220 Vac ±15% |
| Rated Output Current (A) | 16 A/32A |
PWM Duty Cycle | 26.7%/53.3% |
| Maximum Output Power (kW) | 3.5 kW/7.0kW |
| Cable Length (m) | 3.5 m |
Input Characteristics | |
Input Voltage (V) | 220 Vac ±15% |
| Input Current (A) | 16 A |
| AC Input Frequency (Hz) | 45~55 |
Safety Characteristics | |
| Dielectric Withstand Voltage (Input – Enclosure) | 2000 Vac 1 min 10 mA |
| Dielectric Withstand Voltage (Output – Enclosure) | 2000 Vac 1 min 10 mA |
| Insulation Resistance (Input to Enclosure, DC500V) | ≥10 MΩ (ambient relative humidity 90%, no condensation) |
Insulation Resistance (Output to Enclosure, DC500V) | ≥10 MΩ (ambient relative humidity 90%, no condensation) |
Mechanical Parameters | |
| Dimensions (H × W × D) (mm) | 360 × 260 × 145 mm (wall-mounted) / Pole height 1300 mm |
| Weight (kg) | ≤3 kg (wall-mounted), ≤6.5 kg (pole-mounted) |
| Incoming Cable Specification | National standard AC220V 3×6 mm² |
| Installation Method | Wall-mounted / Pole-mounted |
EMC Characteristics | |
Radiated Susceptibility (RS) | 80 MHz~1 GHz 10 V/m, 80% AM |
| Conducted Susceptibility (CS) | 150 kHz~80 MHz 10 V, 80% AM |
| Electrical Fast Transient / Burst (EFT) | ±2 kV |
| Environmental Characteristics | |
Operating Temperature (°C) | -20 ~ +50 |
| Storage Temperature (°C) | -40 ~ +70 |
| Transportation Temperature (°C) | -40 ~ +70 |
| Relative Humidity | ≤95% |
| Atmospheric Pressure (kPa) | 70 ~ 106 |
Altitude | ≤2000 m |
| Ingress Protection Rating | IP54 |
Protection Features | |
Output Short-circuit Protection | No output after protection, non-self-recoverable (requires manual reset) |
| Output Overcurrent Protection | No output after protection, non-self-recoverable (requires manual reset) |
| Output Overvoltage Protection | No output after protection, self-recoverable (no manual reset required) |
| Input Undervoltage Protection | Power reduction after protection, self-recoverable (no manual reset required) |
| PWM Abnormality Protection | No output after protection, non-self-recoverable (requires manual reset) |
| Emergency Stop Protection | No output after protection, non-self-recoverable (requires manual reset) |
| AC Leakage Protection | No output after protection, non-self-recoverable (requires manual reset) |
| Connection Abnormality Protection | No output after protection, self-recoverable |
Other Parameters | |
| Standby Power Consumption | ≤2 W |
| Hot-swap Requirement | Peripheral devices shall support hot-swap capability. |
| Failure Isolation | After peripheral device failure, it shall be reliably isolated from the system. |
Packaging and Transportation | Suitable for Class III highway transportation over 3000 km |
Cable Entry Method | Bottom entry |
Environmental Requirement | RoHS6 compliant |
| Mean Time Between Failures (MTBF) | ≥8796 hours |
| Configured Protection | AC type residual current device (RCD) |
NB/T 33001-2018 Technical Conditions for Off-board Conductive Chargers for Electric Vehicles